The cookie settings on this website are set to 'allow all cookies' to give you the very best experience. Please click Accept Cookies to continue to use the site.

Rat IL1 beta CLIA Kit (RTES00012)

(No reviews yet) Write a Review
SKU:
RTES00012
$738

Description

Rat IL1 beta (Interleukin 1 Beta) CLIA Kit

This kit uses Sandwich-CLIA as the method. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Rat IL1 beta . Standards or samples are added to the appropriate micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat IL1 beta and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat IL1 beta, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit (RLU) value is measured spectrophotometrically by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat IL1 beta. The concentration of Rat IL1 beta in the samples can be calculated by comparing the RLU of the samples to the standard curve.

Assay typeSandwich
Format96T
Assay time4.5h
ReactivityRat
Detection methodChemiluminescence
Detection range12.50-800 pg/mL
Sensitivity7.50 pg/mL
Sample volume100uL
Sample typeSerum, plasma and other biological fluids
RepeatabilityCV < 15%

Specificity

This kit recognizes Rat IL1 beta CLIA Kit in samples. No significant cross-reactivity or interference between Rat IL1 beta CLIA Kit and analogues was observed.

Typical Data

As the RLU values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

Concentration
(pg/mL)
RLU Average Corrected
80052069
53215
5264252616
40020854
22614
2173421708
20010384
9032
97089682
1004428
4676
45524526
502323
2053
21882162
251110
1010
10601034
12.50497
521
509483
025
27
26--

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Rat IL1 beta CLIA Kit were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Rat IL1 beta CLIA Kit were tested on 3 different plates, 20 replicates in each plate.

  Intra-assay Precision Inter-assay Precision
Sample123123
n202020202020
Mean (pg/mL)36.4983.36301.9038.3077.17276.82
Standard deviation3.898.9930.104.298.2122.84
C V (%)10.6610.789.9711.2010.648.25

Recovery

The recovery of Rat IL1 beta CLIA Kit spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range (%) Average Recovery (%)
Serum (n=5)90-10496
EDTA plasma (n=5)100-115107
Cell culture media (n=5)94-109102

Linearity

Samples were spiked with high concentrations of Rat IL1 beta CLIA Kit and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

    Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2Range (%)100-11597-11496-109
Average (%)109104101
1:4Range (%)97-11387-10097-113
Average (%)10393104
1:8Range (%)95-11094-10587-101
Average (%)10110092
1:16Range (%)101-11298-11397-112
Average (%)107106103

Kit Components & Storage

An unopened kit can be stored at 4'C for 1 month. If the kit is not used within 1 month, store the items separately according to the following conditions once the kit is received.

Item Specifications Storage
Micro CLIA Plate(Dismountable)8 wells ×12 strips-20'C, 6 months
Reference Standard2 vials
Concentrated Biotinylated Detection Ab (100×)1 vial, 120 uL
Concentrated HRP Conjugate (100×)1 vial, 120 uL-20'C(shading light), 6 months
Reference Standard & Sample Diluent1 vial, 20 mL4'C, 6 months
Biotinylated Detection Ab Diluent1 vial, 14 mL
HRP Conjugate Diluent1 vial, 14 mL
Concentrated Wash Buffer (25×)1 vial, 30 mL
Substrate Reagent A1 vial, 5 mL4'C (shading light)
Substrate Reagent B1 vial, 5 mL4'C (shading light)
Plate Sealer5 pieces
Product Description1 copy
Certificate of Analysis1 copy
View AllClose

Additional Information

Reactivity:
Rat
ELISA Type:
CLIA
View AllClose